Automated System with Ethylene and Carbon Dioxide Removal


Completely automated ripening systems which is also called as centralized ripening system consists of :
  • Gas Cylinder Bank
  • Gas analyzers
  • Centralized ripening controller.

Ripening is done completely by the system automatically. It controls the complete ripening cycle of 4 days and no user intervention is require. The controller activates the ripening cycle by a simple switch which starts the ripening cycle. It doses the room with ethylene for 16 to 24 hrs which can be set by the user. It measures and doses the room continuously to maintain is to 100 ppm. For the next 3 days the CO2 is controlled and maintained below 1 % levels. It controls the CO2 levels using ventilation fans or CO2 scrubber. The system is controlling all the parameters which are required of ripening hence every batch coming out of the system is uniform and consistent over a period of time. This is the ultimate goal of the customer.

The Procedure:
  • Precool the banana to 18 to 20 degrees
  • Switch on the ripening controller
  • Open the door after 4 days

Who Should Buy This
  • Customers having single cold rooms or scatterd cold rooms
  • Customer who are using cold rooms for multipurpos appications

Technical Specifications of Gas Analyzer.
  • Power Source : 24 V DC OR 230 V AC Adapter
  • Display : 3 1/2 digit LED display
  • Keypad : 3 keys
  • Calibration : Electronic calibration with password protect and diagnostics for sensor depletion and recalibration.
  • Choice of Sensors : Ethylene (0-500 ppm)
  • Range : 0-500 ppm
  • Resolution : 1 ppm
  • Accuracy : 1% of full scale
  • Alarm outputs : High Alarm (90db buzzer)
  • User Configurable Relay Output : NO/NC for relay logics. Hysterisys configurable
  • Analogue Outputs : 4-20mA or 0-2 Volts as per customers request

Technical Specifications PF Ripening Controller
  • Power Source : 230 V A/C with 1 hour Power Backup
  • Display : Multi character graphic display indicating all Ripening Parameters
  • Key Pad : 4 keys for entering various values and process parameters
  • Control Switches : 1 control switches to activate the ripening process
  • Sensor Range : CO2 (0-5 %), Ethylene (0-500 ppm)
  • Alarms : Ethylene High and Carbon Di oxide High
  • Sensor Break, Sensor Drift, Over Range
  • Input Channels : 2 channel inputs with 1 for ethylene and 1 for CO2
  • All inputs are 4-20 mA with load upto 500 Ohms
  • Output Channels : 4 relays for ethylene control and CO2 controls
  • NO/NC 230 volts supply
  • Ethylene Control : User settable gas concentration and dosing time complete manual overide
  • Carbon Dioxide Control : User settable value and complete manual overide
  • Calibration : Electronic Calibration wih auto cal facility
  • Data Logging & Analysis : Capture, Transfer & Report Data On PC
  • Software : Adjustable Sample (Up to 10000) & Rate(1-255 sec)
  • Built In Thermal Printer Instant Record Of measurement Reading